Skip to content

Specifications

Babo (°Babo)

Accuracy: ±0.2
Resolution: 0.1
Range: 0 to 30
ATC: Yes

Baumé (°Bé)

Accuracy: ±0.2
Resolution: 0.1
Range: 0 to 40
ATC: Yes

Brix (°Bx)

Accuracy: ±0.2
Resolution: 0.1
Range: 0 to 85
ATC: 10 to 100°C
         18 to 40°C¹

¹ Automatic Temperature Compensation ICUMSA model is valid for the defined temperature range

Corn syrup AC 28 DE (%w/w) *

Accuracy: ±0.3
Resolution: 0.1
Range: 0 to 70
ATC: 20 to 60°C

* Measurement unit available with Lab Meister Pro mobile app

Corn syrup AC 42 DE (%w/w) *

Accuracy: ±0.3
Resolution: 0.1
Range: 0 to 70
ATC: 20 to 60°C

* Measurement unit available with Lab Meister Pro mobile app

Corn syrup AC 55 DE (%w/w) *

Accuracy: ±0.3
Resolution: 0.1
Range: 0 to 84
ATC: 20 to 60°C

* Measurement unit available with Lab Meister Pro mobile app

Corn syrup DC 32 DE (%w/w) *

Accuracy: ±0.3
Resolution: 0.1
Range: 0 to 84
ATC: 20 to 60°C

* Measurement unit available with Lab Meister Pro mobile app

Corn syrup DC 63 DE (%w/w) *

Accuracy: ±0.3
Resolution: 0.1
Range: 0 to 84
ATC: 20 to 60°C

* Measurement unit available with Lab Meister Pro mobile app

Corn syrup DC 70 DE (%w/w) *

Accuracy: ±0.3
Resolution: 0.1
Range: 0 to 84
ATC: 20 to 60°C

* Measurement unit available with Lab Meister Pro mobile app

Corn syrup DC 95 DE (%w/w) *

Accuracy: ±0.3
Resolution: 0.1
Range: 0 to 74
ATC: 20 to 60°C

* Measurement unit available with Lab Meister Pro mobile app

Cutting oil (%oil)

Accuracy: ±0.2
Resolution: 0.1
Range: 0 to 100
ATC: 10 to 100°C

Ethylene glycol (%v/v)

Accuracy: ±0.4
Resolution: 0.1
Range: 0 to 60
ATC: 10 to 80°C

Ethylene glycol (%w/w)

Accuracy: ±0.4
Resolution: 0.1
Range: 0 to 60
ATC: 10 to 80°C

Ethylene glycol (°C EG)

Accuracy: ±0.5
Resolution: 0.1
Range: -40 to 0
ATC: 10 to 40°C

Ethylene glycol (°F EG)

Accuracy: ±1
Resolution: 0.1
Range: -40 to 32
ATC: 10 to 40°C

Freezing point E.G (°C)

Accuracy: ±0.5
Resolution: 0.1
Range: -40 to 0
ATC: Yes

Freezing point E.G (°F)

Accuracy: ±1
Resolution: 0.1
Range: -40 to 32
ATC:Yes

Freezing point P.G (°C)

Accuracy: ±0.5
Resolution: 0.1
Range: -40 to 0
ATC: Yes

Freezing point P.G (°F)

Accuracy: ±1
Resolution: 0.1
Range: -40 to 32
ATC: Yes

Fructose (%w/w Fru) *

Accuracy: ±0.2
Resolution: 0.1
Range: 0 to 85
ATC: 10 to 85°C
         15 to 30°C¹

* Measurement unit available with Lab Meister Pro mobile app
¹ Automatic Temperature Compensation ICUMSA model is valid for the defined temperature range

Glucose (%w/w Glc) *

Accuracy: ±0.2
Resolution: 0.1
Range: 0 to 85
ATC: 10 to 85°C
         15 to 30°C¹

* Measurement unit available with Lab Meister Pro mobile app
¹ Automatic Temperature Compensation ICUMSA model is valid for the defined temperature range

HFCS 42% (%w/w) *

Accuracy: ±0.5
Resolution: 0.1
Range: 0 to 84
ATC: 20 to 60°C

* Measurement unit available with Lab Meister Pro mobile app

HFCS 55% (%w/w) *

Accuracy: ±0.3
Resolution: 0.1
Range: 0 to 84
ATC: 20 to 60°C

* Measurement unit available with Lab Meister Pro mobile app

HFCS 90% (%w/w) *

Accuracy: ±0.3
Resolution: 0.1
Range: 0 to 84
ATC: 20 to 60°C

* Measurement unit available with Lab Meister Pro mobile app

HMCS 42% (%w/w) *

Accuracy: ±0.3
Resolution: 0.1
Range: 0 to 84
ATC: 20 to 60°C

* Measurement unit available with Lab Meister Pro mobile app

HMCS 50% (%w/w) *

Accuracy: ±0.3
Resolution: 0.1
Range: 0 to 84
ATC: 20 to 60°C

* Measurement unit available with Lab Meister Pro mobile app

Honey moisture (%water)

Accuracy: ±0.2
Resolution: 0.1
Range: 13 to 25
ATC: 10 to 30°C

Invert sugar (%w/w IS) *

Accuracy: ±0.2
Resolution: 0.1
Range: 0 to 85
ATC: 10 to 85°C
         15 to 30°C¹

* Measurement unit available with Lab Meister Pro mobile app
¹ Automatic Temperature Compensation ICUMSA model is valid for the defined temperature range

KMW (°KMW)

Accuracy: ±0.2
Resolution: 0.1
Range: 0 to 30
ATC: Yes

Oechsle CH (°Oe CH)

Accuracy: ±1
Resolution: 1
Range: 0 to 205
ATC: Yes

Oechsle GER (°Oe GER)

Accuracy: ±1
Resolution: 1
Range: 20 to 205
ATC: 10 to 85°C

Plato (°P)

Accuracy: ±0.2
Resolution: 0.1
Range: 0 to 40
ATC: 10 to 100°C

Potential Alcohol Brix (%v/v)

Accuracy: ±0.2
Resolution: 0.1
Range: 0 to 25
ATC: 10 to 100°C

Potential Alcohol Oe (%v/v)

Accuracy: ±0.2
Resolution: 0.1
Range: 0 to 25
ATC: 10 to 100°C

Practical salinity units (PSU)

Accuracy: ±2
Resolution: 1
Range: 0 to 50
ATC: 10 to 40°C

Propylene glycol (%v/v PG)

Accuracy: ±0.4
Resolution: 0.1
Range: 0 to 50
ATC: 10 to 100°C

Propylene glycol (%w/w PG)

Accuracy: ±0.4
Resolution: 0.1
Range: 0 to 50
ATC: 10 to 100°C

Propylene glycol (°C PG)

Accuracy: ±0.5
Resolution: 0.1
Range: -40 to 0
ATC: 10 to 40°C

Propylene glycol (°F PG)

Accuracy: ±1
Resolution: 0.1
Range: -40 to 32
ATC: 10 to 40°C

Refractive index nD

Accuracy: ±0.0003
Resolution: 0.0001
Range: 1.3330 to 1.5040
ATC: No

Refractive index nD @20 °C

Accuracy: ±0.0003
Resolution: 0.0001
Range: 1.3330 to 1.5040
ATC: 10 to 100°C

Salinity (SG 20/20)

Accuracy: ±0.002
Resolution: 0.001
Range: 1.000 to 1.114
ATC: 10 to 40°C

Salinity (ppt)

Accuracy: ±2
Resolution: 1
Range: 0 to 150
ATC: 10 to 40°C

Temperature (°C)

Accuracy: ±0.5
Resolution: 0.1
Range: 10 to 100
ATC: No

Temperature (°F)

Accuracy: ±0.9
Resolution: 0.1
Range: 50 to 212
ATC: No

Total dissolved solids (%TDS)

Accuracy: ±0.2
Resolution: 0.1
Range: 0 to 25
ATC: 10 to 100°C

Total dissolved solids custom (%TDS) **

Accuracy: ±0.2
Resolution: 0.1
Range: 0 to 25
ATC: 10 to 100°C

** For the calculation, you can enter a factor between 0.80 and 0.90

Sample volume

approx. 0.4 mL

Ambient temperature

10 °C to 40 °C / 50 °F to 104 °F

Storage temperature

10 °C to 40 °C / 50 °F to 104 °F

Humidity

5 % to 95 % relative air humidity, non-condensing

Interface

Bluetooth Low Energy

Power supply

2x AAA 1.5V LR03 alkaline batteries (included) or AAA NiMH rechargeable batteries

Battery operation lifetime

~10.000 measurements

Dimensions

108 mm x 64 mm x 35 mm (4.3 in x 2.5 in 1.4 in)

Weight (incl. batteries)

approx. 135 g (0.31 lbs.)

Mobile Operating System

iOS & Android

Ingress protection

IP66 according IEC 60529

Sample area

Stainless stell and glass, FKM O-Ring

ATC

Automatic Temperature Compensation model 10 to 100 °C